<ErrorNumber>18016</ErrorNumber>
<ErrorFamily>Laser</ErrorFamily>
<ErrorMessage>
LASER: not ready &lt;timeout&gt; seconds after laser on command
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Green</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The ADLAS laser timeout is controlled by the nvs parameter laser tinit.
The default value is set to 10 minutes.
</text></DescriptionText>
<DescriptionText><text>
If the laser is recalibrating infrequently (once a shift, or less), then
increase the laser tinit value.
</text></DescriptionText>
<DescriptionText><text>
If the laser is recalibrating  more often, then reset the laser power set point.
Try setting laser power to a new higher value, and then back
to the original to see if it will stabilize. Do not set the laser power outside
of the range 80 - 100 mW. For more details see the HRX service intranet pages (see
link below)
</text></DescriptionText>
<DescriptionText><text>
If the laser is always recalibrating during imaging, then check the cables
to the exposure head and laser power supply.
</text></DescriptionText>
<DescriptionText><text>
If none of the above helps, the laser may be failing and require replacement.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Click on 'Resume" if possible.  In any case, contact Creo Service since the
platesetter likely needs servicing.
</text></DescriptionText>
</OperatorAction>
<Cause>
Laser power supply or cable is faulty
</Cause>
<Cause>
Laser is failing
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/laser_cfg_tinit.xml</LinkAddress><LinkTitle>NVS: laser tinit</LinkTitle></Link>
<Link><LinkAddress>../commands/laser.xml</LinkAddress><LinkTitle>Command: laser</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:48 2008 PST